# Sequence description: reading rules

How a Pulseq file and an MRD stream are read into a
{class}`~blochsim.SequenceDescription`. What a description gives a simulator
is summarised on {doc}`../../explanations/description`; how it is packed for the
kernels is {doc}`kernels`.

## Events

| Kind | Timestamp | Payload, in wire order |
| --- | --- | --- |
| `WAIT` | block start | none |
| `RF` | pulse isocentre, `delay + center` | definition id, use, amplitude, phase (rad), frequency offset (Hz), shim id, slice-select gradient (Hz/m) |
| `ADC` | sample nearest the readout's own $k = 0$ | role, phase (rad), echo flag |

Timestamps are in microseconds from the start of the repetition read. The
payload is positional, which is why an event's fields are reached through
named properties (`rf_amplitude_hz`, `adc_role`, ...) rather than by index.

Each event also carries an action word (`EventAction`): `CRUSH_BEFORE` and
`CRUSH_AFTER` around a refocusing pulse, `SHIFT_AFTER` and `SPOIL_AFTER` after
a sample. A description read from a file or a stream has no actions; they are
added when the events are re-emitted through a simulator's handlers.

### RF use

The use tag is Pulseq's: `EXCITATION`, `REFOCUSING`, `INVERSION`,
`SATURATION`, `PREPARATION`, `OTHER`, or `UNKNOWN` where the file is silent.
{meth}`~blochsim.Simulator.from_description` sends `REFOCUSING`,
`INVERSION` and `SATURATION` to the handlers of the same name and every other
use to `excitation`, so a refocusing pulse reaches the refocusing handler
whatever angle it turns.

### ADC role and echo flag

The role relates a sample to the other samples of its repetition: `SINGLE`
where a repetition takes one and where several are alike, `ECHO_CENTER` for
the one nearest the centre of a train whose samples are not alike,
`NON_CENTER` for the rest, and `NON_ACQUIRED` for a window that records
nothing. The echo flag says whether the position reaches $k = 0$.
`record="all"` keeps every ADC event, `"acquired"` those whose role is not
`NON_ACQUIRED`, and `"echo"` those flagged.

## Pulseq block conversion

A Pulseq file is a table of blocks, each holding at most one RF pulse, one
gradient per axis and one ADC window. One block becomes one event: a block with
a pulse is an RF event, one with an ADC and no pulse an ADC event, any other a
WAIT. Gradients are not events.

The file is parsed and its trajectory computed by pypulseq; a sequence in memory with pypulseq's reading
interface, pypulseq's or pypulseqpp's, is read the same way. The gradients are
read for two things only: the k-space trajectory that places each ADC event,
and the slice-select amplitude under each pulse's isocentre, the magnitude of
the vector the three axes play there.

### Repetition selection

The `TRSize` definition states how many blocks one repetition holds, and
reading is refused without it: the period is declared by the design, not
searched for. The repetition read is, in order of precedence, `tr_index`
(counted in whole repetitions), the file's `TRRef` definition, and the first
repetition that acquires. The last is refused when the acquiring repetitions
play different pulses (compared by shape and flip angle, so an RF-spoiling
phase increment is no difference), as in an optimised echo train or a
fingerprinting schedule.

```python
from blochsim.simulators import FSESimulator

# The tissue is given; the echo spacing, the train length, the refocusing
# angle and the pulse shapes are read.
train = FSESimulator.from_pulseq("fse.seq", states=20)
signal = train.simulate(T1=830.0, T2=80.0)
```

## RF definitions

An RF event names a definition. Pulseq writes a library row per pulse
occurrence, so RF spoiling writes one row per repetition of the same shape;
rows with the same magnitude, phase and time shapes (normalised to their peak)
collapse onto one definition.

A definition can carry a phase per sample, sample times of its own, a
slice-select gradient per sample, up to eight frequency bands, and one envelope
per transmit channel. Which of those are present decides the rotation mode;
see {doc}`epg`.

### Flip angle

The flip angle of an event is $2\pi\,|A \int e(t)\,\mathrm{d}t|$ for the event
amplitude $A$ and the definition's envelope $e$, integrated on the RF raster
the description carries (`rf_raster_time_s`). Sample times are stored in units
of that raster, so a pulse whose dwell differs from the raster keeps its
duration; reading a description against a raster other than the one its shapes
were written on scales every flip angle by the ratio.

The two sources normalise differently:

| Source | Envelope | Event amplitude |
| --- | --- | --- |
| Pulseq file, {func}`~blochsim.rf_definition` | integral $1/(2\pi)$ s | flip angle in radians |
| MRD stream | peak of one | Hz |

A pulse played under a slice-select gradient $G$ is given the bandwidth
$G\,\Delta z$, where $\Delta z$ is the reference slice thickness: the
excitation's small-tip bandwidth, the full width at half maximum of its
envelope's Fourier transform, over its own gradient. Slice positions are then
in units of $\Delta z$ for every pulse of the repetition, so a refocusing pulse
designed for a wider slice selects a wider one. A pulse with no gradient keeps
a bandwidth of zero and stays non-selective, and the gradient is read at the
pulse centre, so a gradient that varies under the pulse is not followed.
A pulse with unevenly spaced sample times is refused,
since a definition read from a file is played one sample per dwell.

## Echo detection

A Pulseq file does not say which sample is the echo; the trajectory
$k = \gamma \int G\,\mathrm{d}t$ does. A readout's centre is the sample where
the axes that readout sweeps come closest to zero, an axis being swept when
its span across the readout exceeds $10^{-6}$ of its largest absolute
coordinate there (or of 1 m$^{-1}$, whichever is larger).

```{figure} /generated/figures/description_echo.png
:width: 100%
:alt: Eight k-space lines, one through the origin, and their distances from it.

One repetition of a spin-echo train. Every readout sweeps through its own zero
in the readout direction; one of the eight is also at the centre of the
phase-encode direction.
```

Two questions follow, answered over every instance of an ADC position in the
file.

**Whether a position bears an echo** is absolute. Its smallest $|k|$ at the
centre sample is compared with the scan's own closest approach to $k = 0$,
within $10^{-5}$ of the largest coordinate the scan reaches plus $10^{-6}$
m$^{-1}$. A finite phase-encode offset stays out and accumulated
floating-point error stays in.

**What a position's role is** is structural. The norm is taken only along the
axes the readout sweeps, so a CPMG echo is central whatever line it encodes.
Where a repetition takes several samples, those within $10^{-3}$ of the
largest of these norms from the smallest are central and the rest
`NON_CENTER`. A single central sample is `ECHO_CENTER`; several central
samples, as every echo of a CPMG train or every blade of a PROPELLER, are all
`SINGLE`.

The train in the figure is the tied case: all eight roles are `SINGLE`, and one
echo flag is set.

## MRD stream

Pulserver's reconstruction proxy reads the sequence file a series was played
from and sends its description after the MRD XML header and before the first
acquisition, as ISMRMRD waveforms, which every MRD writer keeps with the series:
per file of the sequence chain a header (`waveform_id` 1024) and an event list
(1025), and one waveform per RF definition (1026). Each carries one vector of
32-bit words led by its length, over as many channels as keep a channel within
65 535 samples; floats are bit-cast and float64 values take two words, low then
high.

- Header: format version, subsequence index, number of subsequences, number of
  events, number of RF definitions, `tr_duration_us`, `rf_raster_time_s`.
- Event list: subsequence index, number of events, then ten words an event:
  type, `timestamp_us` (float64), and the seven float32 parameters in the wire
  order above.
- RF definition: subsequence index, id, bandwidth, number of bands, eight band
  offsets, band bandwidth, a word left 0, then for the magnitude, phase and time
  shapes whether each is given and its uncompressed and stored sample counts,
  then the samples of those given.

{func}`~blochsim.read_mrd_description` reads the stream up to the last of
them, passing the physiological waveforms over, returns the XML header and the
descriptions in play order, and leaves the stream at the first acquisition;
{func}`~blochsim.description_from_waveforms` reads them off the waveforms of a
stored series. A message other than a filename, config, header, text or
waveform before the description is refused. The description
carries no shim definitions, no per-sample slice-select gradient, no crusher
dephasing or voxel size, and no event actions.

## Gradients

A Pulseq file has no gradient use, so a crusher cannot be told from a phase
encode without following the k-space moment through the whole repetition, and
an EPG simulation quantises that moment to whole orders. A description
therefore carries one dephasing for the sequence, `crusher_dephasing_rad`, the
turn one unbalanced gradient winds across a voxel of `voxel_size_m`; their
ratio scales diffusion and flow, and a dephasing of zero leaves both out.

Which gradients play around each pulse and sample comes from the simulator's
handlers (see {doc}`../../explanations/signal-model`):

```python
from blochsim.simulators import FSESimulator, MRFSimulator

# The same file, read as a refocused train and as an unbalanced one.
refocused = FSESimulator.from_pulseq("scan.seq")
unbalanced = MRFSimulator.from_pulseq("scan.seq")
```

A moment that is not a whole number of orders has no representation: a bipolar
pair, a velocity-encoding lobe, a crusher of twice its neighbour's area. A
preparation's own spoiler does not survive either, since a handler reinstates
what a pulse or a sample implies and a gradient alone is neither.